RoHSTesting
Legal basis
The EU RoHS directive 2002/95/EC EU RoHS Directive 2002/95/EC
We formally implemented in July 1, 2006
The European Parliament and the Council of the European Union in June 8, 2011 released No. 2011/65/EU on the rewrite directive restricting the use of certain hazardous substances in electrical and electronic equipment, RoHS2.0.
The effective date: July 21, 2011. EU country should be within 18 months, in January 2, 2013 before the completion of transformation of national law, then 2002/95/EC (RoHS1.0) and all of its revision instruction abolished.
The EU announced in June 4, 2015 (EU) 2015/863 instruction, will be adjacent benzene two formic acid two (2- ethylhexyl) ester (DEHP), dibutyl phthalate (DBP), butyl benzyl phthalate two formic acid (BBP) and two formic acid isobutyl phthalate two (DIBP) listed in the RoHS2.0 appendix II restricted substances list. So far. 10 kinds of material has reached RoHS 2 Appendix II restriction list. Electrical and electronic equipment during the transition period to July 22, 2019, medical equipment and monitoring equipment of the transition period to July 22, 2021. For belonging to the electronic
The other kind of toy products, DEHP, BBP, DBP content is required in accordance with REACH regulations in Appendix VII X control requirements.
Scope of application
1, suitable for the launch of the EU market, Annex 1 list of 11 categories of electrical and electronic products and related components, materials and other 11 categories of products include: large household appliances and small household appliances; IT; communication equipment; consumer equipment; lighting equipment; electric tools; toys, leisure and sports equipment; medical equipment; video control equipment, including industrial monitoring and control equipment; vending machine; not covered in the above categories all other electrical and electronic equipment. But does not apply to Article 2 (4) listed in the product or equipment.
2, the implementation of this Directive shall not contravene the European Union's legislation on safety and health requirements and legislation on chemicals, in particular (EC) 1907/2006 regulations, and the European Union's special legislation on waste management
Core requirements
1, the RoHS2.0 directive, the control of products according to the calculation of "homogeneous" material (Homogenous material), the lead (Pb), mercury (Hg), six chromium (Cr (VI)), polybrominated biphenyls (PBBs), polybrominated diphenyl ether (PBDEs), adjacent benzene two formic acid (2 - two ethylhexyl) phthalate ester (DEHP), two formic acid butyl benzyl phthalate (BBP), two Ding Jizhi (DBP), two formic acid isobutyl phthalate two formic acid two (DIBP) of the content should not exceed 1000ppm, cadmium (Cd) content shall not exceed 100ppm.
2, after the entry into force of the RoHS2.0 completely replace RoHS1.0, the new product implementation stages: control management of medical equipment and video surveillance equipment included in the control since July 22, 2014, will be included in the control from July 22, 2016 and July 22, 2017 medical and industrial monitoring of in vitro diagnostic equipment, the final product categories from July 22, 2019 onwards into the control.
3, certain exemptions may be granted in accordance with annexes 3 and 4, because of the current economic or technical failure to replace products / materials
4, according to the provisions of article sixteenth of the 2011/65/EU, the CE logo affixed to the product shows that the product will not only comply with the relevant coordination instructions (such as EMC, LVD etc.), but also in line with the requirements of the RoHS2.0 directive issued by the European Union. At the same time, according to the official RoHS2.0 FAQ said: since January 2, 2013, the CE logo will become the products meet unique RoHS2.0.
5, electronic and electrical equipment shall be affixed CE mark at the same time the manufacturer should write the corresponding technical documentation and the EU declaration of conformity right before being put on the market. In electrical and electronic equipment on the market, the manufacturer / importer and its authorized representatives shall retain the EU declaration of conformity and technical documents for at least 10 years.
RoHS product testing range
The Rohs instruction covers the electronic and electrical products listed in the catalog below AC1000V and below DC1500:
1, large household appliances: refrigerators, washing machines, microwave ovens, air-conditioning and so on;
2, small household appliances: vacuum cleaners, electric irons, hair dryers, ovens, clocks and watches, etc.;
3, IT and communication instruments: computers, fax machines, telephones, mobile phones, etc.;
4, civil devices: Radio, television, video recorders, musical instruments and so on;
5, lighting appliances: in addition to home lighting, such as fluorescent lamps, lighting control devices;
6, power tools: electric drills, lathes, welding, sprayers, etc. (other large industrial tools need to be installed);
7, toys / entertainment, sports equipment: electric cars, TV games;
8, medical instruments: radiation therapy apparatus, ECG tester, analytical instruments, etc.;
9, surveillance / control equipment: smoke detectors, thermostats, factory monitoring and control machines, etc.;
Testing service of RoHS certification
1.XRF scan;
2. quantitative testing of hazardous substances;
3.XRF scan + chemical quantitative test;
4.RoHS2.0 consulting and training services;
5. provide CE-RoHS technical documentation services according to RoHS2.0 coordination standards;
6.RoHS reporting integration