LED Lamps

LED lamp test

LED semiconductor lighting

      LED (Light Emitting Diode), also known as light-emitting diodes, they use solid semiconductor chip as luminescent materials, when the two ends with forward voltage, carrier in semiconductor composite, release of excess energy caused by photon emission of visible light.

In recent years, with the research on semiconductor luminescent material continuously thorough, continuous progress and new material manufacturing process (LED nitride crystal and fluorescent powder) in the development and application of ultra high brightness LED color has made a breakthrough, the luminous efficiency is increased by about 1000 times, color has been achieved all the colors of the visible light band, one of the most important is the emergence of super high brightness white LED, make LED applications across the high efficiency lighting market as possible. It has been pointed out that high brightness LED will be human after Edison invented the incandescent bulbs, one of the greatest inventions.
 

The excellent characteristics of LED:

high luminous efficiency

Low power consumption

long service life

High safety and reliability

greens environmental protection

 

 

Lamps and accessories test laboratory
Lamps and accessories test laboratory in Europe, Australia, Middle East, America directly authorized specialized laboratory, can be used in EN60598-2-X, AS/NZS60598-2-X, IEC60598-2-X of all lamps, EN60968, IEC60968, AS/NZS60968, EN60238, IEC60238, AS, /NZS60238, AS/, NZS3170, AS/NZS3140, EN61347, AS/NZS61347, IEC61347, IEC62031 lamps and accessories test our test report is more authoritative, more effective, promote trade competitiveness


The main test items of lamps

tab

The external connection and internal wiring

Dustproof, waterproof and anti solid particles

 

structure

 

Insulation resistance and electric strength

 

Creepage distance and clearance

 

PROVISION FOR EARTHING

 

Durability test and thermal test

 

Heat resistant, fire resistance and resistance to tracking

 

Protection against electric shock

 

screw terminal

 

Screwless terminals and electrical connections

 

 

Lamps and accessories test list

lamps and lanterns

 

Lamps first part: General requirements and test
GB 7000.1-2007
IEC 60598-1:2008
AS/NZS 60598.1:2013
J 60598-1(H14)
EN 60598-1:2008

luminaires for emergency lighting

 

Luminaires - Part 2-22: Particular requirements for emergency lighting

GB 7000.2-2008
IEC 60598-2-22:2008
AS/NZS 60598.2.22:2005
EN 60598-2-22:2008
JIS C8105-2-22:2000

Children with portable luminaires

 

The 2-10 lamps - Part 2: Particular requirements for portable luminaires for children
GB 7000.4-2007           
IEC 60598-2-10:2003
AS/NZS 60598.2.10:1998
EN 60598-2-10:2003

Road and street lighting

 

Luminaires - Part 2-3: Particular requirements for road and street lighting
GB 7000.5-2005
IEC 60598-2-3:2011
EN 60598-2-3:2003

Luminaires with built-in tungsten lamp transformer or converter

 

Luminaires - Part 2-6: special requirements with lamps built-in tungsten lamp transformer or converter
GB 7000.6-2008
IEC 60598-2-6:1994+A1:1996
AS/NZS 60598.2.6:1998

Focus light fixture

 

Luminaires - Part 2-5: Particular requirements for safety requirements for floodlights

GB 7000.7-2005
IEC 60598-2-5:1998 
AS/NZS 60598.2.5:2002
EN 60598-2-5:1998

Lighting chains

 

Luminaires - Part 2-20: Particular requirements for lamp series

GB 7000.9-2008
IEC 60598-2-20:2010
AS/NZS 60598.2.20:2002
EN 60598-2-20:2010 
JIS C8105-2-20:2011

Limit the surface temperature of lamps

 

Luminaires - Part 2-24: Particular requirements limit surface temperature lamp

GB 7000.17-2003
IEC 60598-2-24:2013
EN 60598-2-24:2013

Extra low voltage lighting systems for filament lamps

 

Luminaires - Part 2-19: Particular requirements tungsten lamp for extra low voltage lighting systems

GB 7000.18-2003
IEC 60598-2-23:2001
EN 60598-2-23:1996+A1:2000
JIS C8105-2-23:2004
AS/NZS 60598.2.23:2002 

Non professional photographic lamp etc.

 

Photo and film Luminaires (non professional) safety requirements

GB 7000.19-2005
IEC 60598-2-9:1987+A1:1993
EN 60598-2-9:1989 
JIS C8105-2-9:2011
AS/NZS 60598.2.9:2006 

fixed general purpose luminaires

 

Luminaires - Part 2-1: Particular requirements for fixed general purpose luminaires

 
GB 7000.201-2008
IEC 60598-2-1:1979+A1:1987
AS/NZS 60598.2.1:1998
EN 60598-2-1:1989  
JIS C8105-2-1:1999  
CNS 14335-2-1:2011 

recessed luminaire

 

Luminaires - Part 2-2: Particular requirements for embedded lamps

 
GB 7000.202-2008
IEC 60598-2-2:2011
AS/NZS 60598.2.2:2011

portable general purpose luminaires

 

Luminaires - Part 2-4: Particular requirements: portable general purpose luminaires

GB 7000.204-2008
IEC 60598-2-4:1997
AS/NZS 60598.2.4:2005 +A1:2007
EN 60598-2-4:1997 
JIS C8105-2-4:2010  
CNS 14335-2-4:2011

Portable luminaires for garden use

 

Portable luminaires for garden use

GB 7000.207-2008
IEC 60598-2-7:1982+A1:1987+A2:1994
AS/NZS 60598.2.7:2005
EN 60598-2-7:1997 
JIS C8105-2-7:2011

handed lamp

 

Luminaires - Part 2-8: Particular requirements for lantern

GB 7000.208-2008
IEC 60598-2-8:2013
AS/NZS 60598.2.8:2002
EN 60598-2-8:2013  
JIS C8105-2-8:2011

Aquarium luminaires

 

Luminaires - Part 2-11: Particular requirements for Aquarium luminaires

GB 7000.211-2008
IEC 60598-2-11:2013
EN 60598-2-11:2013

Night light socket installation

 

Luminaires - Part 2-12: Particular requirements for night light power socket installation

GB 7000.212-2008 
IEC 60598-2-12:2013
AS/NZS 60598.2.12:2002

Ground recessed luminaires

 

Luminaires - Part 2-13: Particular requirements for ground embedded lamps

GB 7000.213-2008
IEC 60598-2-13:2006+A1:2011

Luminaires for stage lighting and photography etc.

 

Luminaires - Part 2-17: Particular requirements stage lighting, television, film and photographic studios (outdoor and indoor) lamps

GB 7000.217-2008
IEC 60598-2-17:1984 +A1:1987+A2:1990
AS/NZS 60598.2.17:2006
EN 60598-2-17:1989+A2:1991 
JIS C8105-2-17:2011

Luminaires for swimming pools and similar places

 

Luminaires - Part 2-18: lamps for special requirements for swimming pools and similar places


GB 7000.218-2008
IEC 60598-2-18:1993+A1:2011
EN 60598-2-18:1994+A1:2012
AS/NZS 60598.2.18:1998 

Ventilation type lamp

 

Luminaires - Part 2-19: Particular requirements ventilation type lamp
GB 7000.219-2008
IEC 60598-2-19:1981+A1:1987+A2:1997
EN 60598-2-19:1998 
JIS C8105-2-19:2010
AS/NZS 60598.2.19:2001 

Luminaires for use in hospitals and rehabilitation clinic building

 

Luminaires - Part 2-25: Particular requirements for luminaires for use in hospitals and rehabilitation clinic building

GB 7000.225-2008
IEC 60598-2-25:1994+ A1:2004
EN 60598-2-25:1994+A1:2004
AS/NZS 60598.2.25:2001 

Emergency lighting and power equipment

 

Emergency lighting and power equipment


ANSI/UL 924-2011

In-line night lights

 

In-line night lights

 
ANSI/UL 1786-2011

UL portable general purpose luminaires

 

Portable luminaires

ANSI/UL 153-2011

UL lamp

 

Lamp


ANSI/UL 1598-2010

Seasonal and holiday decoration products

 

Seasonal and holiday decoration product safety

ANSI/UL 588-2009

The Christmas tree and other decorative lighting

 

General requirements for Christmas trees and other decorative lighting components

CSA C22.2 No.37-M1989

Flexible lighting products

 

Flexible lighting products

ANSI/UL 2388-2010

Self ballasted lamps and adapter

 

Self ballasted lamps and adapter

ANSI/UL 1993-2012

of a lamp controlgear

 

The first part of the lamp control device: general and safety requirements

GB 19510.1-2009
IEC 61347-1:2012
AS/NZS 61347.1:2002
EN 61347-1:2008+A2:2013

of a lamp controlgear

 

The first part of the lamp control device: general and safety requirements

GB 19510.1-2009
IEC 61347-1:2012
AS/NZS 61347.1:2002
EN 61347-1:2008+A2:2013

electronic transformer

 

Lamp controlgear - Part 2-2: electronic transformer special requirements

GB 19510.3-2009
IEC 61347-2-2:2011
AS/NZS 61347.2.2:2007

Supplied electronic ballasts for tubular fluorescent lamps

 

The fourth part of the lamp control device: Particular requirements for a.c. supplied electronic ballasts for fluorescent lamps
GB 19510.4-2009
Lamp controlgear - Part 2-3: Particular requirements AC electronic ballast for fluorescent lamp

 
IEC 61347-2-3:2011
AS/NZS 61347.2.3:2004 

ballasts for tubular fluorescent lamps

 

The ninth part of the lamp control device: Particular requirements for ballasts for fluorescent lamps

GB 19510.9-2009
The lamp control device - Part 2-8: Particular requirements for ballasts for tubular fluorescent lamps

IEC 61347-2-8:2006
AS/NZS 61347.2.8:2003

Discharge lamps (excluding tubular fluorescent lamp ballast)

 

The tenth part of the lamp control device discharge lamps (excluding tubular fluorescent lamps) - Particular requirements for ballasts

GB 19510.10-2009
Lamp controlgear - Part 2-9: discharge lamps (excluding tubular fluorescent lamps) with special requirements ballast

IEC 61347-2-9:2012
AS/NZS 61347.2.9:2004

The two luminescence tube module electronic control device for DC / AC

 

The fourteenth part of the lamp control device: Particular requirements for DC or AC electronic control device with LED module

GB 19510.14-2009
Lamp controlgear - Part 2-13: two luminescence tube module with the special requirements of electronic control device for DC / AC

IEC 61347-2-13:2006
EN 61347-2-13:2006

High intensity discharge lamp ballasts

 

High intensity discharge lamp ballasts

 
ANSI/UL 1029-2011

The bulb (safety)

 

Incandescent lamps - Safety requirements - part first: with tungsten filament lamps for domestic and similar general lighting
GB 14196.1-2008
IEC 60432-1:2011

Light bulb (performance)

 

Domestic and similar general lighting lamps Performance requirements

GB/T 10681-2009
IEC 60064:1993+A1:2000+A2:2002+A3:2005+A4:2007+A5:2009 

Self ballasted electrodeless fluorescent lamps for general lighting (safety)

 

Self ballasted electrodeless fluorescent lamp safety requirements for general lighting

GB 21554-2008

Self ballasted lamps (safety)

 

Self ballasted lamps for general lighting safety requirements

GB 16844-2008
IEC 60968:2012 

Self ballasted lamps (performance)

 

Self ballasted fluorescent lamps for general lighting performance requirements

GB/T 17263-2013
IEC 60969:2001 

Single end fluorescent lamp (safety)

 

Safety requirements for single end fluorescent lamp

GB 16843-2008
IEC 61199:2012

Single capped fluorescent lamps (performance)

 

Single end fluorescent lamp performance requirements

GB/T 17262-2011
IEC 60901:2007:1996+A1:1997+A2:2000+A4:2007+A5:2011

double-capped fluorescent lamps

 

Double end fluorescent lamp safety requirements

GB 18774-2002
IEC 61195:2012 

Starter for fluorescent lamp

 

Starter for fluorescent lamp

GB 20550-2006 
IEC 60155:1993+A1:1995+A2:2006
QB 2276-1996 
AS/NZS 60155:2000+A2:2000

Using LED module for general lighting

 

LED modules for general lighting safety requirements

GB 24819-2009 
IEC 62031:2012

50V self ballasted LED lamp (safety)

 

General lighting self ballasted lamps more than 50V LED safety requirements

GB 24906-2010
IEC 62560:2011
EN 62560:2012

Self ballasted lamps LED (performance)

 

Self ballasted lamps - Performance requirements LED for general lighting

GB/T 24908-2010
IEC 62612:2013

screw socket

 

screw socket
GB 17935-2007 
IEC 60238:2011
EN 60238:2004+C1:2005+A2:2011
AS/NZS 3140:2007
JIS C8302:1995/A1:2009
AS/NZS 60238:2007 

UL screw lampholders

 

Screw socket

UL 496-2008REV.4:2011 

bayonet socket

 

bayonet socket

GB 17936-2007
IEC 61184:2011
AS/NZS 61184:2007
AS/NZS 3117:2007

Miscellaneous lampholders

 

Miscellaneous lampholders - part first: General requirements and test

GB 19651.1-2008
IEC 60838-1:2011

LED connector

 

Miscellaneous lampholders - Part 2-2: Particular requirements for LED connector module

GB 19651.3-2008
IEC 60838-2-2:2012 

 

Share To:
Copyright © 2016 Shenzhen POCE technology CO. LTD All Rights Reserved
Address:1F,Bldg.H, Hongfa Science and Technology park, Tangtou, Shiyan, Bao’an District, Shenzhen,China
H5 building (electromagnetic compatibility EMC experiment building) of shiyan tong tou hongfa science park, baoan district, shenzhen